The FG-BBOX-LL is a satellite device of the TTK FG-NET Digital Unit. It is designed to be connected with FG-OD oil leak detection range of sense cables, for industry Long Line application.
Similar to FG-BBOX, the FG-BBOX-LL is monitored by FG-NET via a standard Ethernet network. It expands FG-NET to manage two additional circuits of sense cables with up to 118* (2 x 59) addresses of additional Sense Cables.
The FG-BBOX-LL detects multiple simultaneous leak locations to the concerned sense
FG-BBOX-LL
FEATURES
- Up to 118 FG-OD range of Sense Cables can be managed independently providing a maximum protected length of 1416m (118 x 12m) for both circuits.
- No physical jumper cable or distance limit between FG-NET unit and FG-BBOX-LL.
- Up to 16 FG-BBOX-LL can be connected to one FG-NET unit without exceeding a total number of 500 Digital Sense Cables per FG-NET.
- TCP/IP connection via standard RJ45 socket.
- Relay type: Volt Free Contact NO/NC.
- 4 Relay contacts: 2 leak relays (1 for each circuit), 1 cable break relay and 1 power failure relay.
BENEFITS
- Dynamic Leak Evolution Analysis - The magnitude of a leak and its evolution in time can be analysed through the alarm logs. The number and sequence of addressable sections which report a leak, together with their timestamp, allow to monitor the leak’s progression in time.
- Multiple simultaneous leaks can be detected and located (118 cables = 118 potential alarms).
- Each sense cable is addressable and can be assigned a specific name.
- Cable break faults can be detected (to the concerned cable). When a cable break occurs, the system maintains its integrity by continuing to monitor all preceding cables for faults.
- Extension and upgrade of the system is easy.
TECHNICAL DATA
Compatibility | Digital units: FG-NET, FG-NET-LL Sense cables, Point sensor: FG-OD, FG-ODC, FG-ODR, FG-ODP |
Dimensions | W: 175 mm H: 220 mm D: 55 mm |
Maximum Length of Sense Cable | Up to 1416m (2 circuits x 59 lengths x 12m) per unit (connected with 1000m jumper cable and Zener barrier MTL7760ac or equivalent) |
Accuracy | To the concerned sense cable |
System Capacity | Up to 16 FG-BBOX-LL can be monitored by 1 FG-NET or FG-NET-LL |
Supply Voltage | 100-240VAC 0.35A 50/60Hz |
Maximum Power Consumption | 15W |
Working Temperature Range | -15°C to 55°C |
Working Humidity Range | 5% to 80% non-condensing |
Relay Types | Volt free contact (NO, NC, COM) |
Relay Numbers | 4 |
Connectivity | RJ45 |
Maximum Relay Switching Voltage | 125 V AC and 220 V DC |
Maximum Relay Switching Capacity | 60 W (30W x 2A) |
Ingress Protection | IP40 - indoor use only |